{"title":"Mechanical Filtrations","description":"Ensure cleaner processes with Lab Pro’s Mechanical Filtrations, designed to efficiently remove particles and contaminants from air, gas, and liquid systems. Perfect for laboratory, cleanroom, and industrial use. Available in various types and sizes to meet your application needs. Browse our selection below. For bulk orders, contact us at 888-4-LABPRO (888-452-2776). Next-day service in California and same-day will-call service available. \u003c!-- split --\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/filtration\"\u003e Filtration \u003c\/a\u003e\u003c\/li\u003e","products":[{"product_id":"hepa-filter-99997-efficient-at-03-microns-and-ac6036lf-acfhepa48","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns. Replacement for AC4000HLF-52, AC8000HLF-52 and AC6036LF - ACFHEPA48","description":"HEPA filter, 99.997% efficient at 0.3 microns. Replacement for AC4000HLF-52, AC8000HLF-52 and AC6036LF - ACFHEPA48\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 50in(W) x 14in(D) x 4.5in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265944666261,"sku":"ACFHEPA48","price":875.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_89c09040-5052-4cca-928d-c9a9acae0a58.jpg?v=1776347026"},{"product_id":"44-wide-particulate-board-hepa-filter-for-metal-free-applications-acfhepa44w","title":"AirClean 44?wide particulate board HEPA filter for metal free applications - ACFHEPA44W","description":"44” wide particulate board HEPA filter for metal free applications - ACFHEPA44W\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 7in(W) x 49in(D) x 26in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265944895637,"sku":"ACFHEPA44W","price":1050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_e077f71f-2b34-4adb-b91d-abf189ef3d5f.jpg?v=1776347030"},{"product_id":"pack-of-12-prefilters-acfpre","title":"AirClean Pack of 12, prefilters  - ACFPRE","description":"Pack of 12, prefilters  - ACFPRE\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 18in(W) x 2in(D) x 13in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265944928405,"sku":"ACFPRE","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_dd157187-05a2-4a2b-8c8f-3ab2248fcff1.jpg?v=1776347031"},{"product_id":"hepa-filter-99997-efficient-at-03-microns-wood-frame-acfhepaw","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns- wood frame - ACFHEPAW","description":"HEPA filter, 99.997% efficient at 0.3 microns- wood frame - ACFHEPAW\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 13in(W) x 30in(D) x 4in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265945059477,"sku":"ACFHEPAW","price":425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_ed592f8b-f78d-4c3b-ab57-b9cc917a8390.jpg?v=1776347027"},{"product_id":"hepa-filter-99997-efficient-at-03-microns-acfhepa44","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA44","description":"HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA44\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 7in(W) x 49in(D) x 26in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265945256085,"sku":"ACFHEPA44","price":775.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_0d81c03e-5526-44b7-9a24-04d14f8c8f0e.jpg?v=1776347032"},{"product_id":"pack-of-12-prefilters-acflfpre","title":"AirClean Pack of 12, prefilters  - ACFLFPRE","description":"Pack of 12, prefilters  - ACFLFPRE\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 10in(W) x 9in(D) x 6in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265945485461,"sku":"ACFLFPRE","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_9af74dd5-8594-414d-8986-fde0641800bf.jpg?v=1776347030"},{"product_id":"68-wide-particulate-board-hepa-filter-for-metal-free-applications-acfhepa68w","title":"AirClean 68\" wide particulate board HEPA filter for metal free applications - ACFHEPA68W","description":"68\" wide particulate board HEPA filter for metal free applications - ACFHEPA68W\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 72in(W) x 27in(D) x 11in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265946239125,"sku":"ACFHEPA68W","price":1450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_273aeb6a-f511-4c19-8853-d1ca501fe3af.jpg?v=1776347035"},{"product_id":"pack-of-12-prefilters-acfpre3","title":"AirClean Pack of 12, prefilters  - ACFPRE3","description":"Pack of 12, prefilters  - ACFPRE3\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 28in(W) x 18in(D) x 16in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265946370197,"sku":"ACFPRE3","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_e1ff61f4-188b-4a8a-9f82-f306c9df9366.jpg?v=1776347033"},{"product_id":"hepa-filter-99997-efficient-at-03-microns-acfhepa42","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA42","description":"HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA42\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 44in(W) x 14in(D) x 4.5in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265946599573,"sku":"ACFHEPA42","price":750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_f5890754-9a1a-4e21-93b9-0b32dc97e329.jpg?v=1776347035"},{"product_id":"hepa-filter-99997-efficient-at-03-microns-acfhepa72","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns.  - ACFHEPA72","description":"HEPA filter, 99.997% efficient at 0.3 microns.  - ACFHEPA72\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 76in(W) x 28in(D) x 12in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265946665109,"sku":"ACFHEPA72","price":1400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_71586102-6033-4c3a-8a04-11af276f0b25.jpg?v=1776347038"},{"product_id":"hepa-filter-99997-efficient-at-03-microns-wood-frame-acfhepa48w","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns- wood frame - ACFHEPA48W","description":"HEPA filter, 99.997% efficient at 0.3 microns- wood frame - ACFHEPA48W\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 50in(W) x 14in(D) x 4.5in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265946828949,"sku":"ACFHEPA48W","price":950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_e9c5d52a-fd4b-4f85-b54f-ccc71d3ca9ae.jpg?v=1776347035"},{"product_id":"pack-of-12-prefilters-acfpre9","title":"AirClean Pack of 12, prefilters  - ACFPRE9","description":"Pack of 12, prefilters  - ACFPRE9\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 18in(W) x 16in(D) x 28in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265946861717,"sku":"ACFPRE9","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_25244a92-f80f-48d8-b584-28a0c34d5fce.jpg?v=1776347033"},{"product_id":"ulpa-filter-999995-efficient-at-012-microns-acfulpa44","title":"AirClean ULPA filter, 99.9995% efficient at 0.12 microns - ACFULPA44","description":"ULPA filter, 99.9995% efficient at 0.12 microns - ACFULPA44\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 13in(W) x 30in(D) x 4in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265946992789,"sku":"ACFULPA44","price":925.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_db09e5f6-a6e9-4ca1-ac87-7eca139def13.jpg?v=1776347041"},{"product_id":"probe-storage-cabinet-pack-of-12-prefilters-acfpre10","title":"AirClean Probe storage cabinet-pack of 12, prefilters  - ACFPRE10","description":"Probe storage cabinet-pack of 12, prefilters  - ACFPRE10\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 20in(W) x 12in(D) x 12in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265947418773,"sku":"ACFPRE10","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_2120cc6f-b802-413e-b930-aa650be7864b.jpg?v=1776347040"},{"product_id":"hepa-filter-99997-efficient-at-03-microns-acfhepa56","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA56","description":"HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA56\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 65in(W) x 29in(D) x 12in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265947451541,"sku":"ACFHEPA56","price":1100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_ef520a08-aaba-4d98-b0fb-79b32347a93a.jpg?v=1776347040"},{"product_id":"hepa-filter-99997-efficient-at-03-microns-wood-frame-acfhepa18w","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns- wood frame - ACFHEPA18W","description":"HEPA filter, 99.997% efficient at 0.3 microns- wood frame - ACFHEPA18W\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 30in(W) x 13in(D) x 4in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265947615381,"sku":"ACFHEPA18W","price":425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_b7acc6f8-49c4-48ce-8355-6c78ab39405a.jpg?v=1776347042"},{"product_id":"pack-of-12-prefilters-acflfpre24","title":"AirClean Pack of 12, prefilters  - ACFLFPRE24","description":"Pack of 12, prefilters  - ACFLFPRE24\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 20in(W) x 12in(D) x 12in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265947844757,"sku":"ACFLFPRE24","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_f977c84d-abf8-4bef-be3d-193c45d1c6f5.jpg?v=1776347040"},{"product_id":"pack-of-12-prefilters-acfpre18","title":"AirClean Pack of 12, prefilters  - ACFPRE18","description":"Pack of 12, prefilters  - ACFPRE18\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 18in(W) x 2in(D) x 13in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265947975829,"sku":"ACFPRE18","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_a59c06a1-d2db-44f5-ba9a-9b0b611cea68.jpg?v=1776347038"},{"product_id":"pack-of-12-prefilters-acfpre2","title":"AirClean Pack of 12, prefilters  - ACFPRE2","description":"Pack of 12, prefilters  - ACFPRE2\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 18in(W) x 26in(D) x 16in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265948074133,"sku":"ACFPRE2","price":255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_6cee05a8-9a7a-4f35-989e-f25a789f2a00.jpg?v=1776347041"},{"product_id":"hepa-filter-99997-efficient-at-03-microns-acfhepa68","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA68","description":"HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA68\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 72in(W) x 27in(D) x 11in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265948139669,"sku":"ACFHEPA68","price":1400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_6ba560d7-540c-4ce7-aec0-c1ce7e685313.jpg?v=1776347041"},{"product_id":"pack-of-12-prefilters-acfpre8","title":"AirClean Pack of 12, prefilters  - ACFPRE8","description":"Pack of 12, prefilters  - ACFPRE8\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 20in(W) x 12in(D) x 12in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265948205205,"sku":"ACFPRE8","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_87cd84cc-3d8c-44d2-90f8-6352d03a49a1.jpg?v=1776347040"},{"product_id":"pack-of-12-prefilters-same-as-acfpre-1-but-acfpre11","title":"AirClean Pack of 12, prefilters, same as ACFPRE-1 but for conformal coating applications - ACFPRE11","description":"Pack of 12, prefilters, same as ACFPRE-1 but for conformal coating applications - ACFPRE11\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 18in(W) x 16in(D) x 28in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265948369045,"sku":"ACFPRE11","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_087c2ff9-7ada-4b3d-af44-71df6211cba6.jpg?v=1776347040"},{"product_id":"pack-of-12-prefilters-acfpre6","title":"AirClean Pack of 12, prefilters  - ACFPRE6","description":"Pack of 12, prefilters  - ACFPRE6\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 28in(W) x 18in(D) x 16in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265948598421,"sku":"ACFPRE6","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_c82b5614-16f6-41ae-87ed-b17d0c588de1.jpg?v=1776347043"},{"product_id":"ulpa-filter-999995-efficient-at-012-microns-acfulpa68","title":"AirClean ULPA filter, 99.9995% efficient at 0.12 microns - ACFULPA68","description":"ULPA filter, 99.9995% efficient at 0.12 microns - ACFULPA68\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265948827797,"sku":"ACFULPA68","price":1525.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_b094e7fb-9a73-4029-b7c8-901a6e04b7de.jpg?v=1776347044"},{"product_id":"pack-of-12-prefilters-same-as-acfpre-2-but-acfpre12","title":"AirClean Pack of 12, prefilters, same as ACFPRE-2 but for conformal coating applications - ACFPRE12","description":"Pack of 12, prefilters, same as ACFPRE-2 but for conformal coating applications - ACFPRE12\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 18in(W) x 16in(D) x 28in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265948926101,"sku":"ACFPRE12","price":285.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_8cba409a-c83b-4722-8387-7f8d13aab2c5.jpg?v=1776347043"},{"product_id":"pack-of-12-prefilters-acfpre1","title":"AirClean Pack of 12, prefilters  - ACFPRE1","description":"Pack of 12, prefilters  - ACFPRE1\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 18in(W) x 26in(D) x 16in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265949384853,"sku":"ACFPRE1","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_affa33ba-2e84-4950-8697-ca51246bee0b.jpg?v=1776347044"},{"product_id":"ulpa-filter-999995-efficient-at-012-microns-wood-frame-acfulpa44w","title":"AirClean ULPA filter, 99.9995% efficient at 0.12 microns- wood frame - ACFULPA44W","description":"ULPA filter, 99.9995% efficient at 0.12 microns- wood frame - ACFULPA44W\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 13in(W) x 30in(D) x 4in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265950007445,"sku":"ACFULPA44W","price":1250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_5e7f27e9-2b1c-4b83-81ad-f216536b5169.jpg?v=1776347047"},{"product_id":"ulpa-filter-999995-efficient-at-012-microns-acfulpa18","title":"AirClean ULPA filter, 99.9995% efficient at 0.12 microns - ACFULPA18","description":"ULPA filter, 99.9995% efficient at 0.12 microns - ACFULPA18\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 13in(W) x 30in(D) x 4in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265950728341,"sku":"ACFULPA18","price":385.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_9d1b83ad-3d1a-446b-b1cb-79fb170d2e39.jpg?v=1776347047"},{"product_id":"pack-of-12-prefilters-acfpre4","title":"AirClean Pack of 12, prefilters  - ACFPRE4","description":"Pack of 12, prefilters  - ACFPRE4\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 20in(W) x 12in(D) x 12in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265950761109,"sku":"ACFPRE4","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_43abdf6d-add3-4ea3-972b-788b5e43e1b7.jpg?v=1776347050"},{"product_id":"ulpa-filter-999995-efficient-at-012-microns-wood-frame-acfulpaw","title":"AirClean ULPA filter, 99.9995% efficient at 0.12 microns- wood frame - ACFULPAW","description":"ULPA filter, 99.9995% efficient at 0.12 microns- wood frame - ACFULPAW\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 13in(W) x 30in(D) x 4in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265951088789,"sku":"ACFULPAW","price":475.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_9340c2b0-8620-4cd5-8e2d-3842ea835271.jpg?v=1776347049"},{"product_id":"ulpa-filter-999995-efficient-at-012-microns-acfulpa48","title":"AirClean ULPA filter, 99.9995% efficient at 0.12 microns - ACFULPA48","description":"ULPA filter, 99.9995% efficient at 0.12 microns - ACFULPA48\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 50in(W) x 14in(D) x 4in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265951121557,"sku":"ACFULPA48","price":1075.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_3bf9ec56-ce9f-4e05-87b2-37177addedf6.jpg?v=1776347052"},{"product_id":"pack-of-12-prefilters-acfpre5","title":"AirClean Pack of 12, prefilters  - ACFPRE5","description":"Pack of 12, prefilters  - ACFPRE5\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 48in(W) x 16in(D) x 16in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265951514773,"sku":"ACFPRE5","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_bd791d82-56b1-4844-ac0f-fc1a1906d637.jpg?v=1776347050"},{"product_id":"ulpa-filter-999995-efficient-at-012-microns-wood-frame-acfulpa18w","title":"AirClean ULPA filter, 99.9995% efficient at 0.12 microns- wood frame - ACFULPA18W","description":"ULPA filter, 99.9995% efficient at 0.12 microns- wood frame - ACFULPA18W\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 13in(W) x 30in(D) x 4in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265952661653,"sku":"ACFULPA18W","price":475.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_9f35cb07-3cea-4af1-9864-b205a64c2895.jpg?v=1776347058"},{"product_id":"pack-of-12-prefilters-acflfpre7","title":"AirClean Pack of 12, prefilters  - ACFLFPRE7","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey performance benefit:\u003c\/strong\u003e This pack of 12 prefilters provides the crucial initial stage of mechanical filtration for AirClean Systems enclosures. They effectively remove sub-micron particulates, ensuring that the adsorption filter is protected from contaminants like smoke and acid mists, thereby enhancing the overall filtration system's efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial \u0026amp; construction:\u003c\/strong\u003e The prefilters are constructed with high-quality materials designed for durability and optimal performance in laboratory environments. Their robust construction ensures they can withstand the demands of continuous use in ductless hoods, workstations, and enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRisk reduction \/ compliance benefit:\u003c\/strong\u003e By removing sub-micron particulates, these prefilters significantly reduce the risk of contamination in sensitive laboratory settings. They help maintain compliance with stringent laboratory safety standards, ensuring a safer environment for operators and samples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection level:\u003c\/strong\u003e These prefilters offer a high level of protection by capturing airborne particulates before they reach the adsorption filter. This not only extends the life of the more expensive adsorption filters but also maintains cleaner airflow within the enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort \u0026amp; usability:\u003c\/strong\u003e Designed for ease of use, these prefilters can be quickly and easily installed in a variety of AirClean Systems enclosures. Their compatibility with multiple setups makes them a versatile choice for laboratory managers seeking efficient and straightforward filtration solutions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety \u0026amp; compliance assurance:\u003c\/strong\u003e While specific certifications are not listed, these prefilters are engineered to meet the rigorous demands of laboratory environments, ensuring they contribute to a compliant and safe working space.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eRecommended For\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDuctless fume hoods\u003c\/li\u003e\n\u003cli\u003eLaboratory workstations\u003c\/li\u003e\n\u003cli\u003eEnclosure contamination control\u003c\/li\u003e\n\u003cli\u003eSmoke and acid mist filtration\u003c\/li\u003e\n\u003cli\u003eAirborne particulate reduction\u003c\/li\u003e\n\u003cli\u003eOperator safety enhancement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct Details\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e Pack of 12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltration Type:\u003c\/strong\u003e Mechanical particulate prefilter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Removal of sub-micron particulates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Uses:\u003c\/strong\u003e Ductless hoods, workstations, enclosures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContaminants Reduced:\u003c\/strong\u003e Smoke, acid mists, airborne particulates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePrimary Industries\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli\u003eChemical research facilities\u003c\/li\u003e\n\u003cli\u003eBiotechnology companies\u003c\/li\u003e\n\u003cli\u003eEnvironmental testing labs\u003c\/li\u003e\n\u003cli\u003eIndustrial manufacturing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265952759957,"sku":"ACFLFPRE7","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/Visual1072_eb99b4fc-9b25-4d0e-a39b-a13d1fd1f3e0.png?v=1784125971"},{"product_id":"ulpa-filter-999995-efficient-at-012-microns-acfulpa42","title":"AirClean ULPA filter, 99.9995% efficient at 0.12 microns - ACFULPA42","description":"ULPA filter, 99.9995% efficient at 0.12 microns - ACFULPA42\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 15in(W) x 9in(D) x 44in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265953382549,"sku":"ACFULPA42","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_33d8a3f8-76ff-479c-bdb5-5f292a143cad.jpg?v=1776347062"},{"product_id":"probe-storage-cabinet-hepa-filter-99997-efficient-at-03-microns-acfhepa188","title":"AirClean Probe Storage Cabinet-HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA188","description":"Probe Storage Cabinet-HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA188\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 30in(W) x 13in(D) x 4in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265962983573,"sku":"ACFHEPA188","price":385.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_f66688d0-3701-444b-860d-9cd1cb5a01d1.jpg?v=1776347097"},{"product_id":"teachaide-pack-of-4-ul-listed-prefilters-acffrpre","title":"AirClean TeachAide-pack of 4, UL listed prefilters - ACFFRPRE","description":"TeachAide-pack of 4, UL listed prefilters - ACFFRPRE\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 18in(W) x 28in(D) x 16in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265963573397,"sku":"ACFFRPRE","price":395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_c6bada72-f1c8-41a8-a634-440231d843f9.jpg?v=1776347096"},{"product_id":"teachaide-pack-of-4-ul-listed-prefilters-acffrpre18","title":"AirClean TeachAide-pack of 4, UL listed prefilters - ACFFRPRE18","description":"TeachAide-pack of 4, UL listed prefilters - ACFFRPRE18\u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"col-lg-12\"\u003e\n         \u003cp class=\"mt-2 mb-4\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-lg-12 mt-2 mb-3\"\u003e \n\u003cp\u003eAirClean\u003csup\u003e®\u003c\/sup\u003e Systems ductless hoods, workstations and enclosures provide either operator safety or sample protection from airborne particulate and contamination. The products are designed to incorporate different types of mechanical filtration depending on the application challenge. The first mechanical filtration media is the particulate pre-filter followed by either a HEPA or ULPA filter to capture the fine particulate or potential biological material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END DESCRIPTION--\u003e\n\n\u003c!--PRE FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eParticulate Pre-filters\u003c\/h4\u003e\n\u003cp\u003eThe particulate pre-filter is an electrostatically charged fiber filter which effectively removes submicron particulates. It is designed to protect the adsorption filter from contaminants such as smoke, acid mists, and other submicron particulates. All units are initially supplied with a pre-filter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END PRE FILTER--\u003e\n\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eULPA Filters\u003c\/h4\u003e\n\u003cp\u003eUltra Low Particulate Air (ULPA) Filters are available in various configurations for the containment of particles. This filter has a 99.999% efficiency rating for collecting 0.12 microns.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c!--HEPA FILTER--\u003e\n\u003cdiv class=\"col-lg-12 mt-3 mb-3\"\u003e\n\u003ch4 class=\"\"\u003eHEPA Filters\u003c\/h4\u003e\n\u003cp\u003eHigh Efficiency Particulate Air (HEPA) Filters are available in various configurations for the containment of particles. The filter has a 99.997% efficiency rating for collecting 0.3 micron particles.\u003c\/p\u003e\n \n\u003cp\u003eEach ductless hood, workstation or enclosure, that uses mechanical filtration, has an electronic method of monitoring the efficiency of the installed filtration media. The controller package, either AirSafe™ or UVTect™, incorporates an electronic pressure sensor that constantly monitors the filter plenum pressure. If adverse conditions arise, the end user will be alerted by an audible and visible alarm. These alarms indicate either the reduction of face velocity to a level that will not provide containment or that an ISO 5 condition is not being maintained. AirClean Systems laminar flow and ductless hoods are engineered to remove the guess work and allow the smart technology to ensure operator or sample protection from airborne contaminates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--END HEPA FILTER--\u003e\n\u003cp\u003e\u003c\/p\u003e\n        \u003c\/div\u003e \u003cbr\u003e\u003cbr\u003e\u003cb\u003eShipping Dimensions: \u003c\/b\u003e 20in(W) x 12in(D) x 12in(H)","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265963868309,"sku":"ACFFRPRE18","price":375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_61bdbf53-5a1b-48b6-ad91-75c23926837a.jpg?v=1776347098"},{"product_id":"hepa-filter-99997-efficient-at-03-microns-acfhepa18","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA18","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey performance benefit:\u003c\/strong\u003e The ACFHEPA18 HEPA filter offers exceptional air purification with a 99.997% efficiency at capturing particles as small as 0.3 microns. This high level of performance ensures that even the most minute contaminants are effectively removed from the air, safeguarding both personnel and sensitive materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial \u0026amp; construction:\u003c\/strong\u003e Constructed with high-density filter media, the ACFHEPA18 is housed in a robust frame designed for durability and reliability. This construction ensures long-term performance and stability within various filtration systems, maintaining structural integrity under continuous use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRisk reduction \/ compliance benefit:\u003c\/strong\u003e The ACFHEPA18 helps facilities meet stringent air quality standards by effectively reducing airborne particulates and biological contaminants. This compliance with high-efficiency filtration requirements is crucial for maintaining safe and controlled environments in sensitive applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection level:\u003c\/strong\u003e With its ability to capture 99.997% of particles at 0.3 microns, the ACFHEPA18 provides superior protection against dust, bacteria, and viral agents. This ensures a clean and safe atmosphere in environments where air purity is critical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort \u0026amp; usability:\u003c\/strong\u003e Designed for ease of use, the ACFHEPA18 is simple to install and integrate into existing ductless filtration systems. Its user-friendly design minimizes downtime during filter changes, enhancing operational efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety \u0026amp; compliance assurance:\u003c\/strong\u003e While specific certifications are not listed, the ACFHEPA18 is engineered to meet high-efficiency filtration standards, making it a reliable choice for maintaining compliance with industry air quality requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e99.997% efficient at 0.3 microns\u003c\/li\u003e\n\u003cli\u003eDesigned for use in ductless hoods and cleanroom workstations\u003c\/li\u003e\n\u003cli\u003eCaptures fine particulate and biological contaminants\u003c\/li\u003e\n\u003cli\u003eEasy-to-install filter for high-efficiency filtration systems\u003c\/li\u003e\n\u003cli\u003eCompatible with various filtration enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eLaboratory fume hoods\u003c\/li\u003e\n\u003cli\u003eCleanroom environments\u003c\/li\u003e\n\u003cli\u003eElectronics manufacturing\u003c\/li\u003e\n\u003cli\u003eProtection against airborne particulate and biological contamination\u003c\/li\u003e\n\u003cli\u003eDuctless filtration systems for environmental safety\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBenefits\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eProvides high-efficiency filtration with 99.997% removal of 0.3-micron particles\u003c\/li\u003e\n\u003cli\u003eEnsures clean air in controlled environments, improving worker and product safety\u003c\/li\u003e\n\u003cli\u003eEasy to integrate into ductless filtration systems\u003c\/li\u003e\n\u003cli\u003eSuitable for use in various industries, including healthcare, pharmaceuticals, and electronics\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eRecommended For\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eLaboratory fume hoods\u003c\/li\u003e\n\u003cli\u003eCleanroom environments\u003c\/li\u003e\n\u003cli\u003eElectronics manufacturing\u003c\/li\u003e\n\u003cli\u003ePharmaceutical production\u003c\/li\u003e\n\u003cli\u003eHealthcare facilities\u003c\/li\u003e\n\u003cli\u003eEnvironmental safety systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct Details\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e 99.997% at 0.3 microns\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Ductless fume hoods, cleanroom workstations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e ACFHEPA18\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePrimary Industries\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eHealthcare\u003c\/li\u003e\n\u003cli\u003ePharmaceuticals\u003c\/li\u003e\n\u003cli\u003eElectronics manufacturing\u003c\/li\u003e\n\u003cli\u003eLaboratory research\u003c\/li\u003e\n\u003cli\u003eCleanroom operations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265971142805,"sku":"ACFHEPA18","price":295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/mechanical-filtration-550_04b901de-8844-4e16-bb80-a440c227a7de.jpg?v=1776347121"},{"product_id":"hepa-filter-99997-efficient-at-03-microns-acfhepa","title":"AirClean HEPA filter, 99.997% efficient at 0.3 microns - ACFHEPA","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey performance benefit:\u003c\/strong\u003e The AirClean HEPA filter ensures 99.997% efficiency at capturing particulates as small as 0.3 microns. This level of performance exceeds typical HEPA standards, making it ideal for environments that require ultra-clean air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial \u0026amp; construction:\u003c\/strong\u003e Constructed with pleated microglass media, the filter is housed within a rigid anodized aluminum frame. This design not only enhances durability but also optimizes airflow and reduces resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRisk reduction \/ compliance benefit:\u003c\/strong\u003e The ACFHEPA filter meets ISO 14644 and Class 100 (ISO 5) cleanroom standards. This compliance ensures suitability for use in critical environments where contamination control is paramount.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection level:\u003c\/strong\u003e With a filtration efficiency of 99.997% at 0.3 microns and 99.999% at 0.12 microns, the filter offers exceptional protection against aerosols, bacteria, and dust, maintaining a contamination-free workspace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort \u0026amp; usability:\u003c\/strong\u003e Designed for easy integration, this filter is compatible with AirClean ductless fume hoods and laminar flow cabinets. Its low pressure drop maximizes energy efficiency and extends the life of fan motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety \u0026amp; compliance assurance:\u003c\/strong\u003e Each AirClean HEPA filter is individually tested and certified to ensure minimal leakage and consistent airflow resistance, providing reliable performance in critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e99.997% Filtration Efficiency: Captures 0.3 µm particulates, exceeding standard HEPA requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Microglass Media:\u003c\/strong\u003e Optimized pleat spacing ensures high airflow and low resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealed Aluminum Frame:\u003c\/strong\u003e Prevents bypass leakage for reliable containment performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 5 \/ Class 100 Cleanroom Ready:\u003c\/strong\u003e Maintains contamination control in precision environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-Tested \u0026amp; Certified:\u003c\/strong\u003e Each unit is verified for particle retention and airflow uniformity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Pressure Drop:\u003c\/strong\u003e Maximizes energy efficiency and prolongs fan motor life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e Designed for AirClean Systems enclosures but adaptable to most clean-air devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Service Life:\u003c\/strong\u003e Durable construction reduces the need for replacements and downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaminar Flow Cabinets \u0026amp; Workstations:\u003c\/strong\u003e Maintain controlled particle-free airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuctless Fume Hoods:\u003c\/strong\u003e Provide final-stage filtration for chemical or biological safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleanroom Air Systems:\u003c\/strong\u003e Ideal for Class 100 \/ ISO 5 zones or pre-filters in higher-class environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical \u0026amp; Biotech Labs:\u003c\/strong\u003e Ensure contamination-free environments for sensitive processes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronics Manufacturing:\u003c\/strong\u003e Protects microelectronic components from particulates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResearch Facilities \u0026amp; Universities:\u003c\/strong\u003e Support clean air in analytical and teaching laboratories.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBenefits\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Particle Capture:\u003c\/strong\u003e 99.997% efficiency ensures ultra-pure air quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Reliability:\u003c\/strong\u003e Rigid frame design prevents leaks even under continuous use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCost-Effective Performance:\u003c\/strong\u003e Low resistance reduces operating energy costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleanroom Compliant:\u003c\/strong\u003e Meets ISO 14644 and FED-STD-209E Class 100 standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Compatibility:\u003c\/strong\u003e Works with most clean benches, cabinets, and air filtration systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance Frequency:\u003c\/strong\u003e Extended filter life minimizes change-outs and downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eRecommended For\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eLaminar flow cabinets\u003c\/li\u003e\n\u003cli\u003eDuctless fume hoods\u003c\/li\u003e\n\u003cli\u003eCleanroom air systems\u003c\/li\u003e\n\u003cli\u003ePharmaceutical labs\u003c\/li\u003e\n\u003cli\u003eBiotech research facilities\u003c\/li\u003e\n\u003cli\u003eElectronics manufacturing\u003c\/li\u003e\n\u003cli\u003eUniversity laboratories\u003c\/li\u003e\n\u003cli\u003eAnalytical laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct Details\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHEPA Filter:\u003c\/strong\u003e 99.997% efficient at 0.3 microns\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e 99.999%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParticle Size:\u003c\/strong\u003e 0.12 microns\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e 99.997%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParticle Size:\u003c\/strong\u003e 0.3 microns\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePrimary Industries\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePharmaceutical\u003c\/li\u003e\n\u003cli\u003eBiotechnology\u003c\/li\u003e\n\u003cli\u003eElectronics manufacturing\u003c\/li\u003e\n\u003cli\u003eResearch and academia\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandards and Certifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eISO 14644\u003c\/li\u003e\n\u003cli\u003eClass 100 (ISO 5) Cleanroom Standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCategories\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eHEPA \u0026amp; ULPA Filters\u003c\/li\u003e\n\u003cli\u003eAirClean Systems Accessories\u003c\/li\u003e\n\u003cli\u003eCleanroom Air Management Products\u003c\/li\u003e\n\u003cli\u003eFiltration \u0026amp; Contamination Control\u003c\/li\u003e\n\u003cli\u003eLaboratory Safety Equipment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AirClean Systems","offers":[{"title":"Default Title","offer_id":47265978941589,"sku":"ACFHEPA","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/2327\/6437\/files\/Visual1072_b3d1cb2f-1cd5-415a-ae25-1e596aa4d895.png?v=1784131215"}],"url":"https:\/\/checkout.labproinc.com\/collections\/mechanical-filtrations.oembed","provider":"Lab Pro Inc Plus","version":"1.0","type":"link"}